Structural Deck Correction Plan Beam Specification: Replace existing beams with Double 2x12 Treated Southern Pine, Grade #2 or better. Clearly specify and dimension the maximum span of beams according to IRC code R507.5. Ensure spans do not exceed allowable limits (approximately 8'-10'). Column Specification: Clearly indicate use of 4x6 Pressure-Treated Southern Pine posts. Ensure columns comply with IRC R507.4 height requirements. Clearly indicate column heights in the drawing. Column Attachment: Install approved metal beam-to-post brackets (e.g., Simpson Strong-Tie) to securely attach beams to columns. Clearly show bracket types and fastening details in drawing. Diagonal Bracing: Replace temporary bracing with permanent 2x6 Pressure-Treated diagonal bracing. Secure diagonal braces using galvanized structural screws or bolts, clearly indicated on drawings. Hardware and Connections: Clearly specify that all connections must use galvanized steel ties and brackets suitable for permanent structural use. All hardware and fasteners must be hot-dip galvanized or stainless steel, suitable for pressure-treated lumber. Warped Columns: Replace any warped or compromised columns immediately. Clearly specify on drawings the location and dimensions of replacement columns. Finishing: Remove all temporary and sistered elements. Indicate clearly the finished state of all structural elements, ensuring aesthetic consistency with the main structure. Structural Deck Drawing (Include a clear, detailed diagram showing:) Double 2x12 beam placement and maximum span dimensions 4x6 column locations, clearly labeled with heights Approved metal hardware and connection details clearly depicted Placement and dimensions of diagonal 2x6 bracing Locations of all hardware and fasteners Identification of warped columns requiring replacement Final finish notes ensuring consistent aesthetics with the main structure
Keyword: Design 3D
Price: $400.0
3D Design Building Information Modeling Structural Engineering Autodesk AutoCAD Wooden Structure Drafting Structural Detailing
NEED to have SOLIDWORKS available. Should know how to use Mold Tools features (required) in Solidworks. This project should take few hours to finish. (flexible) Add this to the part that is already created. Download the part below. ( Mold - Spatula ) 1. Save the Moving ...
View JobSCOPE - Building inspection for measurment - Convert existing 2000sf structure to 1000sf adu - Convert garage to jadu - Driveway all the way to bak warehouse Involves MEP, engineering and architecture. Address: 5595 Gardendale St. South Gate, CA. 90280 Pay: $1000 NO LIC...
View JobI need 5 sheets to be stamped to remove 2 existing structures and legalization of one garage. The main commercial building it's a restaurant no work needed.. All the scope of work will be outside.
View Job